EnerZipper Home monitors energy usage in real-time
and analyzes device usage patterns to provide
various energy-saving features.
Item | Specification | Item | Specification |
Model name | EnerZipper Home (WM-DR10-S) | Meter type | Indoor use |
Rating | Single-phase two-wire 220V 120(10)A 60Hz | Meter constant | 1000 pulse/kWh |
Power measurement | Effective power measurement | Meter class | Effective Class 1.0 |
Operating temperature | -25 ~ 55 ℃ | Meter type | Standalone meter |
KC Certification | R-R-Nts-WM-DR10 | Power consumption | 2W or less |
Communication | Wireless communication Wi-FiiFi (2.4GHz) | No. of channels | 1 channel |
EnerZipper Home monitors energy usage in
real-time and analyzes device usage patterns
to provide various energy-saving features.
Item | Specification | Item | Specification |
Model name | EnerZipper Home (WM-DR10-S) | Meter type | Indoor use |
Rating | Single-phase two-wire 220V 120(10)A 60Hz | Meter constant | 1000 pulse/kWh |
Power measurement | Effective power measurement | Meter class | Effective Class 1.0 |
Operating temperature | -25 ~ 55 ℃ | Meter type | Standalone meter |
KC Certification | R-R-Nts-WM-DR10 | Power consumption | 2W or less |
Communication | Wireless communication Wi-Fi (2.4GHz) | No. of channels | 1 channel |
READ THE SAFETY PRECAUTIONS CAREFULLY BEFORE USE
AS THEY ARE ESSENTIAL FOR SAFETY.
|
|
|
※ As the surrounding environment can affect the product's lifespan, please avoid installing the product in the following environments:
|
|
🗸 Always disconnect the power before installing the product. 🗸 Electric shock can lead to death. 🗸 We are not responsible for accidents caused by carelessness when installing while the power is supplied. 🗸 Never allow anyone without a national license to install the product. 🗸 Do not touch the exposed terminals. Touching the exposed terminals can cause electric shock and short circuit accidents. 🗸 Before performing maintenance, always confirm that the power is off and disconnect the wires from the device. 🗸 Do not arbitrarily remove the product while the meter is powered on. 🗸 Always check the rating and specifications before installation. 🗸 Before installation, always check the power supply and phase, then wire accordingly. 🗸 During installation and maintenance, ensure that the internal wires do not touch the product, enclosure, or distribution panel cover. 🗸 Do not arbitrarily disassemble or modify the product. Doing so can cause malfunction and fire. 🗸 If the wire connections to the terminals are loose, it can cause overheating and malfunction, so please tighten them firmly. |
· Do not subject the product to shock or vibration during transportation or storage. Subjecting the product to shock or vibration can cause damage.
· Avoid storing the product in places with high temperature, humidity, dust,
harmful gases, chemicals, direct sunlight, heat-generating elements,
or severe vibration.
· Handle the product with extra care to prevent damage caused by
breakage or mishandling.
· Do not move or transport the product by holding the current sensor
or sensor cable.
· After installing the product and before starting operation,
check for any damage, wiring status, and sensor penetration status.
· Install the product in a way that prevents vibration or impact.
· After closing the distribution panel cover, check if the numbers
can be read from the front.
※ As the surrounding environment can affect the product's lifespan,
please avoid installing the product in the following environments:
· Places with high humidity or a high possibility of flooding,
which can cause malfunction or electric shock accidents
· Places where noise, electric fields, or magnetic fields are likely
to occur, such as near motors and air conditioners
· Places with high temperatures, harmful gases, or heavy dust
Places with flammable gases and volatile substances
· Do not disconnect, disassemble, ignite, or short-circuit the product
while the power is being supplied.
· If the wire connections to the terminals are loose,
it can cause overheating and malfunction, so please tighten them firmly.
Before installing the product, please check
if the following items are included.
Please check for any damage to the contents,
sensors, or wires before installation.
1 power meter
1 user manual
Item | Specification |
Width | 32.5mm |
Length | 107mm |
Height | 36.6mm |
Current sensor cable length | 450mm |
Current sensor inner diameter | 13mm |
Item | Specification | 항목 | 사양 |
Model name | EnerZipper Home (WM-DR10-S) | Meter type | Indoor use |
Rating | Single-phase two-wire 220V 120(10)A 60Hz | Meter constant | 1000 pulse/kWh |
Power measurement | Effective power measurement | Meter class | Effective Class 1.0 |
Operating temperature | -25 ~ 55 ℃ | Meter type | Standalone meter |
KC Certification | R-R-Nts-WM-DR10 | Power consumption | 2W or less |
Communication | Wireless communication Wi-Fi (2.4GHz) | No. of channels | 1 channel |
❶
Open the distribution panel cover and turn off the switches in the order of sub-circuit breaker and main circuit breaker.
❷
Remove the inner cover of the distribution panel.
❸
Remove the unused sub-circuit breaker from the distribution panel.
❹
Open the terminal cover of the power meter, loosen the terminal screws, and secure the power meter by pushing it upwards from below the bus bar.Tighten the terminal fixing screws firmly and close the terminal cover of the product.
❺
Loosen the screw of the terminal connected to the red wire at the bottom of the main circuit breaker and disconnect the wire from the breaker.
❻
Ensure that the arrow direction "→" on the current sensor (CT) is pointing downwards,
pass the red wire through the current sensor, connect it to the circuit breaker, and tighten the terminal screw securely.
❼
Close the distribution panel cover, turn on the power in the order of
main circuit breaker and sub-circuit breaker, and complete the work.
❶
Open the distribution panel cover and turn off the switches in the order of
sub-circuit breaker and main circuit breaker.
❷
Remove the inner cover of the distribution panel.
❸
If there is no extra space for a circuit breaker
in the distribution panel, install it externally.
❹
Open the terminal cover of the power meter, loosen the terminal screws,
and secure the power meter using double-sided tape or other means.
❺
Loosen the screw of the terminal connected to the red wire at the bottom
of the main circuit breaker and disconnect the wire from the breaker.
❻
Ensure that the arrow direction "→" on the current sensor (CT) is pointing downwards
pass the red wire through the current sensor, connect it to the circ
❼
Close the distribution panel cover, turn on the power in the order of
main circuit breaker and sub-circuit breaker, and complete the work.
No. | Specification |
1 | Metering item index |
2 | Wi-Fi operation display |
3 | Load indicator |
4 | Power consumption unit |
Blinking at 1-second intervals:
The device can be registered via the SmartThings mobile app.
Blinking at 1-second intervals: Connected to SmartThings.
Steady on: Connected to SmartThings.
The load indicator blinks when electricity is being used.
As a power meter that measures voltage, current, and
power consumption, it alternately displays each item for 3 seconds.
1. If the arrow direction on the LCD screen is reversed [◀]
- Check if the voltage (L - N) wiring is connected in reverse.
- Check the direction (polarity) of the current sensor (CT).
2. If the arrow [▶] is not displayed on the LCD screen
- Check if the current sensor (CT) is installed correctly.
3. If Wi-Fi connection fails
- Check if the Wi-Fi is in the 2.4GHz band.
1. If the arrow direction on the LCD screen is reversed [◀]
- Check if the voltage (L - N) wiring is connected in reverse.
- Check the direction (polarity) of the current sensor (CT).
2. If the arrow [▶] is not displayed on the LCD screen
- Check if the current sensor (CT) is installed correctly.
3. If Wi-Fi connection fails
- Check if the Wi-Fi is in the 2.4GHz band.